Steam Trap Survey Checklist
A comprehensive steam trap survey checklist — covering testing methods, documentation, and failure diagnosis for all trap types.
5 min readUpdated July 2026
Pre-Survey Preparation
- Obtain trap list: Get a list of all steam traps with tag numbers, types, and locations from the CMMS.
- Verify trap tags: Walk the plant and verify all traps are tagged. Tag any untagged traps.
- Prepare tools: Ultrasonic tester, infrared thermometer, contact pyrometer, and survey forms or tablet.
- Schedule survey: Conduct the survey while the steam system is at normal operating pressure and load.
For Each Trap
- Record tag number and location: Identify the trap by its tag number. Note the location and application (drip leg, heat exchanger, tracing).
- Record trap type: Identify the trap type — thermodynamic (TD), float and thermostatic (F&T), or thermostatic.
- Measure upstream temperature: Use a contact pyrometer on the pipe upstream of the trap. Compare to steam saturation temperature at the operating pressure.
- Measure downstream temperature: Measure on the pipe downstream of the trap. Compare to upstream — a significant drop is normal; no drop suggests failed open.
- Ultrasonic test: Place the ultrasonic probe on the trap body. Listen to the sound pattern and compare to the known pattern for the trap type.
- Visual test (if possible): If a test valve is fitted, crack it open and observe the discharge. Intermittent = normal for TD; continuous = possible failed open.
- Diagnose: Based on all tests, classify as: working, failed open (blowing steam), or failed closed (backing up condensate).
- Record results: Log: tag number, type, temperature readings, ultrasonic result, diagnosis, and any notes.
Diagnosis Guide
| Symptom | Likely diagnosis | Action |
|---|---|---|
| Upstream temp = saturation, downstream temp close to upstream, continuous high ultrasonic | Failed open — blowing steam | Schedule replacement |
| Upstream temp below saturation, no ultrasonic sound, no discharge | Failed closed — blocked or stuck | Schedule replacement or cleaning |
| Intermittent ultrasonic, temperature drop across trap | Working — normal operation | No action required |
| Continuous flow sound, steady temp drop, F&T trap | Working — normal for F&T under steady load | No action required |
Post-Survey
- Compile results: Create a survey report with all trap results, failure rate, and estimated steam loss from failed traps.
- Calculate steam loss: Estimate the steam loss from each failed-open trap (use the orifice size and pressure). Calculate the annual fuel cost.
- Prioritise repairs: Prioritise failed-open traps by steam loss cost. Schedule replacements.
- Schedule follow-up: Test replaced traps 2–4 weeks after installation to verify correct operation.