Calculator

Pipe Support Spacing Calculator

Calculate the maximum allowable pipe support spacing from pipe size, material and a deflection limit — to prevent sagging, stress and joint failure.

Interactive toolUpdated July 2026

Inputs

Water 1000, empty/air 0.

Typical limit 3 mm or span/300.

Results

Max Support Span

4.91 m

Carbon Steel, 114.3×6 mm, 1000 kg/m³ fluid

span 4.91 m
L = (384·E·I·δ / 5w)¼ · load 237.8 N/m

How It Works

L = ∜(384·E·I·δ / 5w)

Simply-supported beam under uniform load (pipe + contents weight), deflection-limited. I = second moment of area of the pipe ring; w = weight per metre × g. Concentrated loads (valves, branches) reduce the allowable span.

Digitise your maintenance with PlantLogica

PlantLogica connects to your equipment sensors via PLC, schedules preventive maintenance, logs work offline by voice in the field, and uses AI to predict failures before they happen.