Air Receiver Sizing Calculator

Calculate the correct air receiver tank size for your compressed air system based on compressor flow, operating pressure, and peak demand duration. Understand the sizing formula and selection guidelines.

Interactive toolUpdated July 2026

Inputs

Pressure below which equipment won't operate properly

Duration of the peak demand event

Results

Required Receiver Volume

253 L

Calculated minimum

Recommended Size

380 L

With 50% safety margin

Usable Air Storage

250 CFM

Air available between p_max and p_min

The Sizing Formula

The receiver tank is sized to provide sufficient air storage to meet peak demand without the pressure dropping below the minimum acceptable level:

V = (Q × t × P_atm) / (P_max − P_min)

Where: V = receiver volume (L), Q = air demand (L/s), t = demand duration (s), P_atm = atmospheric pressure (bar), P_max = max operating pressure (bar abs), P_min = min allowable pressure (bar abs)

General Rule of Thumb

  • Minimum: 1 gallon (3.8 L) per CFM of compressor capacity
  • For systems with high peak demand: 2–3 gallons per CFM
  • For VSD compressors: 2 gallons per CFM (VSDs need storage to stabilise control)
  • The receiver should be large enough that the compressor doesn't short-cycle (more than 6–8 starts per hour)
  • Always go larger if in doubt — a larger receiver improves system stability and reduces cycling

Pro tip: Install the receiver tank downstream of the air dryer. This ensures dry air is stored, preventing condensation in the tank. Install a drain (manual or automatic) at the bottom of the tank to remove any condensate that does form.